Micromotor Tester
 
Scope
Applicable to no-load test of DC micromotors
Basic Functions
1. No-load current, speed test
2. No speed sensor required; detect the motor speed directly by spectrum analysis
3. Show the commutator current waveform
4. Show real-time curves of current, speed;
5. CW/CCW test
6. LV startup test, with voltage, pulse time and startup times settable;
7. Magnetic pole test
8. Using motor terminal voltage feedback in internal precision programmable SMPS, fully offset the test circuit voltage drop and keep the voltage actually applied on a motor accurate
9. Built-in programmable SMPS used to automatically limit the output current based on the rated power; when the motor does not rotate or is short circuited during the test in case of motor quality problems or operator error, the instrument can automatically monitor abnormalities and turn off the power in a short time. Once external abnormalities are released, the instrument can automatically resume work. By this way, it keeps the system secure and reliable
10. Manual & auto test modes available; create motor model projects
11. Set limits for test items, issue sound or light alarm in case of test data over-limit, give NG or GO result in the screen, and issue sound or light alarm in case of NG
12. Save test data in Excel, and export them via a USB interface
Optional
Surge Test |
Current Waveform Detection & Analysis |
Pneumatic Fixtures at Both Stations |
Barcode Reading |
Technical Specifications
Model |
K308 |
K258 |
Rated Voltage (V) |
2~30 |
50~250 |
No-Load Current (A) |
0.1~30 |
0.02~5 |
No-Load Speed (RPM) |
500~25000 |
Output Power (W) |
600 |
Voltage Test Accuracy |
±0.2% |
Current Test Accuracy |
±0.5% |
Speed Test Accuracy |
±0.1% (@ 12 bars, 5000 RPM) |
Display |
10-inch color touch screen |
Host Computer |
CPU clock speed 1.6G, hard drive 32G, memory 2G |
Power Supply |
Voltage 220V 50Hz |
Operating Environment |
Temperature 0~40℃, humidity ≤85% |
Outline Dimensions |
W × H × D = 430 × 280 × 280 |
Remarks |
For technical indicators, test functions, system functions, shape & structure, configuration of fixtures & clamps, the ordering requirements shall prevail |
|